Position
|
The list is sorted by this number. You can re-sort using Drag&Drop. Alphanumeric characters are allowed, position numbers can be assigned twice.
|
Batch/Serial
|
Batch/Serial number
|
QC-Order
|
Short description for the measurement position. Right-click to select a default from the default texts. After selection, the method description is also transferred.
see Manage default texts.
|
Methodology
|
Long description. Edit by double-clicking or clicking the "Description" button.
|
Type of input
|
Available types:
Measurement
|
Minimum / Maximum values are considered. The "measurement" tab is displayed. The measured value is OK if it is between the minimum and maximum.
|
Attribute
|
A measuring position can be marked as "OK"
Values can be entered, but will not be checked.
Example:
Check of color
Enter "red" and "OK" for confirmation.
|
Text
|
Position is only displayed. No confirmation or entry.
|
|
Attribute: you can only specify whether it is okay, and include information.
Measurement: Minimum / maximum values are considered.
Text: Only a header line.
|
Desired value,
UoM
|
Specify target value and unit of measure (mm, kg, % etc., UoM is mandatory)
|
Minimum / Maximum
|
The measurement position is released when the measured value lies within this range.
Only possible for entry type "measurement" not for "attribute" or "text".
If no value is entered, "allowed to set OK manually" will be activated automatically at checking.
|
|
Relevant
|
This option must be activated if this measuring point is relevant for the release of the test plan.
This option is always deactivated for type "Text".
Note: For automated release at least one relevant position is required.
|
Print
|
This option must be activated if the measuring position should be printed in a quality control protocol.
|
Test tool
|
A test tool can be selected. Only information – no effect. No reservations or dispatches.
see Tool administration
|
Condition
|
Only inserted if the stored value matches the selected values in query. see conditional testing positions
|
Item rule
|
Measurement position is only inserted if this field is empty or matches the value entered in Item QC-link.
The measurement position can be hidden or displayed depending on the item or document. See Item QC-link - Measurement position - Rule.
|
Manual OK
|
If the option is active, the icon "OK" is displayed in the Measurement sample . There, it is possible to set the position to "OK" even if the measured value is out of allowed range.
For type of entry "Attribute" this option is always active.
Entering values, this option is automatically enabled if no minimum or maximum value was defined.
|
|
Additional release Deactivate
|
By default, each measurement position needs to be checked and released by a second person. Four-eye principle
Important: The person who entering the measured values is not allowed to release them, as well.
If this option is disabled, the measurement position is automatically released, after the field "OK" was set.
Electronic signature is not supported at this level.
|
|