Measurement samples

Production > Quality control > Quality control orders > Edit QC orders > Input per sample > Measurement samples

Top  Previous  Next
Expand/Collapse Toggles

In this window all measured values can be entered for a Sample.

Window is dynamically adjustable. UDF and Templates can be stored. The authorization for QC-order is required.

 

PATH: Production > Quality Control > Samples > select an entry > Samples button > double-click/Open an entry.

QC_measurem_samples

Window qs_qsftpos_edit.psr

 

After all measured values have been registered, in the sample "release 1" is set to status "released". Depending on the settings, a second release follows, "Release 2", a "batch release", a release of the QC-order or the QC order may be automatically closed. See QC-inspection plan – Release.

 

hmtoggle_plus1Definition "Sample ok"
hmtoggle_plus1Definition "Sample blocked"

 

Configuration of the window:

Measurement positions list

Register measured values

Functions

 

See

Quality control orders

 Quality control order - Item master - Quality control - QC-inspection plan

         Register per sample

                 Register measurement position

                         Edit measurement position

         Register per test

                 Register measured values for all samples

         Documents

         Transfer

 

Measurement positions list

Field

Meaning

POS

Number of measurement.

QC-Test

Test title.

Method description

Description of method.

Minimum

Allowed minimum.

Maximum

Allowed maximum.

Target

Target value.

UoM

Unit of measurement.

Sample

Sample ID.

Measurement value

Enter the current value or text.

OK

check mark, if OK or manually, without entering a value.

Release

Release measurement position?

Relevant

check mark, if relevant for release.

Blockage reason ID

Blockage ID. With right-click a blockage reason can be selected. if a valid ID is entered, the blockage reason is filled automatically. Any value can be entered as ID, due to downward compatibility, there is no check .

Blockage reason

Description of blockage reason. ( Remark).

 

Additional fields can be displayed using window settings.

 

Register measuring values

Measured values and attributes can be registered. Blockage reason, valuation and up to 4 additional fields.

 

Control

Enter data on the lower part of the window. Use Cursor up / down and ENTER to jump in the list to the next or previous position.

 

hmtoggle_plus1Graphical display of measured values

The graphic is hidden for texts and attributes. Also, if no minimum or maximum values are given, the graphic is hidden.

Field

Meaning

Measured value

OK

Release

Blockage reason

After selecting a blockage reason "OK" will be disabled if "Block release" was activated in the blockage reason.

 

If a measured value or an attribute has already been stored, the entry is checked and if necessary, "OK" is set again.

Valuation

UDF1 ... UDF4

Free definable fields are set up in Configuration wizard.

 

Functions

Field

Meaning

Update

Documents

Open the Documents screen, in which linked documents are displayed

Change